AmalieBristol 31.1 · Newport, RI
ElectricalHealthy

Battery monitor

Victron Energy · SmartShunt

House battery negative

First-charge review clarified 0.3 kWh ≈ 23 Ah at 13 V. SOC may read wrong until synchronized.

Verify onboard: Confirm all house loads and charge sources pass through the shunt; synchronize SOC after a full charge.

Last serviced

Settings recommended Jul 2025

Open issues

0

Open tasks

0

Parts on record

0

Interval: Review settings after a full charge; inspect connections

Service history

Every logged job that touched this component.

  1. Dialed in SmartShunt settings for the LiTime 230 Ah bank

    Capacity 230 Ah · charged voltage 14.4 V · tail current 2.3 A · Peukert 1.05 · efficiency 99% · floor 10%

    Follow-up: Verify settings and synchronize SOC after a full charge.

    July 26, 2025

Tasks

Planned and completed work for this component.

Nothing planned

No open or past tasks reference this component.

Verify onboard

To verify: Confirm all house loads and charge sources pass through the shunt; synchronize SOC after a full charge.

Edit component

Log maintenance

Add task

app.sailamalie.com · Private owner logbook