Battery monitor
Victron Energy · SmartShunt
House battery negative
First-charge review clarified 0.3 kWh ≈ 23 Ah at 13 V. SOC may read wrong until synchronized.
Verify onboard: Confirm all house loads and charge sources pass through the shunt; synchronize SOC after a full charge.
Last serviced
Settings recommended Jul 2025
Open issues
0
Open tasks
0
Parts on record
0
Interval: Review settings after a full charge; inspect connections
Service history
Every logged job that touched this component.
Dialed in SmartShunt settings for the LiTime 230 Ah bank
Capacity 230 Ah · charged voltage 14.4 V · tail current 2.3 A · Peukert 1.05 · efficiency 99% · floor 10%
Follow-up: Verify settings and synchronize SOC after a full charge.
July 26, 2025