AmalieBristol 31.1 · Newport, RI
ElectricalHealthy

Solar charge controller

Victron Energy · SmartSolar MPPT 100/30

Near batteries

First charge showed max PV 90 W and a 9 h bulk with no absorption/float yet — likely SOC/conditions, no fault proven. Combined charge current must stay under LiTime's ~100 A max.

Verify onboard: Confirm LiFePO4 profile: bulk/absorption 14.2–14.6 V, float 13.5–13.8 V.

Last serviced

First-charge review Jul 2025

Open issues

0

Open tasks

0

Parts on record

1

Interval: Monitor output; inspect connections and strain relief

Service history

Every logged job that touched this component.

  1. Interpreted the solar system's first charge readings

    Renogy 200 W panel, Victron MPPT 100/30, SmartShunt, LiTime battery

    Follow-up: Continue monitoring; verify full-charge synchronization.

    July 31, 2025

Tasks

Planned and completed work for this component.

Nothing planned

No open or past tasks reference this component.

Parts & consumables

Part numbers on record — check confidence before ordering.

MPPT charge controller

Victron SmartSolar MPPT 100/30

Set the LiFePO4 profile; verify fusing and wiring.

Verify onboard

To verify: Confirm LiFePO4 profile: bulk/absorption 14.2–14.6 V, float 13.5–13.8 V.

Edit component

Log maintenance

Add task

app.sailamalie.com · Private owner logbook